Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.302
Filtrar
1.
Ann Noninvasive Electrocardiol ; 29(3): e13113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563226

RESUMO

The anatomy of the His-Purkinje system has been studied, yet there remains a knowledge gap regarding the impact of His bundle pacing and its electrocardiographic implications. This case report highlights the presence of His-Purkinje system pathology without apparent clues on the surface electrocardiogram (EKG). By observing identical QRS morphology with varying HV intervals resulting from different pacing outputs, we demonstrate the presence of an electrical propagation block within the His bundle.


Assuntos
Fascículo Atrioventricular , Ramos Subendocárdicos , Humanos , Eletrocardiografia/métodos , Estimulação Cardíaca Artificial/métodos
2.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38564374

RESUMO

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Adulto Jovem , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/efeitos adversos , Sistema de Condução Cardíaco , Ventrículos do Coração , Resultado do Tratamento
3.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457487

RESUMO

AIMS: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS: Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION: Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.


Assuntos
Marca-Passo Artificial , Realidade Virtual , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Desenho de Equipamento , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos
4.
J Emerg Med ; 66(4): e492-e502, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38453595

RESUMO

BACKGROUND: Transvenous pacemaker placement is an integral component of therapy for severe dysrhythmias and a core skill in emergency medicine. OBJECTIVE: This narrative review provides a focused evaluation of transvenous pacemaker placement in the emergency department setting. DISCUSSION: Temporary cardiac pacing can be a life-saving procedure. Indications for pacemaker placement include hemodynamic instability with symptomatic bradycardia secondary to atrioventricular block and sinus node dysfunction; overdrive pacing in unstable tachydysrhythmias, such as torsades de pointes; and failure of transcutaneous pacing. Optimal placement sites include the right internal jugular vein and left subclavian vein. Insertion first includes placement of a central venous catheter. The pacing wire with balloon is then advanced until electromechanical capture is obtained with the pacer in the right ventricle. Ultrasound can be used to guide and confirm lead placement using the subxiphoid or modified subxiphoid approach. The QRS segment will demonstrate ST segment elevation once the pacing wire tip contacts the endocardial wall. If mechanical capture is not achieved with initial placement of the transvenous pacer, the clinician must consider several potential issues and use an approach to evaluating the equipment and correcting any malfunction. Although life-saving in the appropriate patient, complications may occur from central venous access, right heart catheterization, and the pacing wire. CONCLUSIONS: An understanding of transvenous pacemaker placement is essential for emergency clinicians.


Assuntos
Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Bradicardia/etiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicações , Síndrome do Nó Sinusal/terapia
5.
J Am Heart Assoc ; 13(4): e032386, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38348809

RESUMO

BACKGROUND: Metabolic disorder is noted for pacing-induced cardiomyopathy. The benefits of His bundle pacing over right ventricular (RV) pacing in preventing pacing-induced cardiomyopathy from a metabolic perspective are yet to be fully understood. METHOD AND RESULTS: Three pig groups were established for this study: sham control, RV pacing (RV pacing for 6 months), and His pacing (RV pacing for 6 months, followed by His bundle pacing for 3 months). Complete atrioventricular block was created in the last 2 groups. Left ventricular function and dyssynchrony were assessed via echocardiography, while proteins linked to metabolism, endoplasmic reticulum stress, and inflammation in left ventricular myocardium were examined. The RV pacing group had significantly more left ventricular mechanical dyssynchrony compared with the other groups. The RV pacing group exhibited triglyceride and diacylglycerol accumulation in cardiomyocytes and higher expression of binding immunoglobulin protein and tumor necrosis factor-α than the other groups. Additionally, the expression of CD36 was activated, while the expression of hormone-sensitive lipase was downregulated in the RV pacing group compared with the His pacing and sham control groups. Furthermore, the expressions of GLUT4 and pyruvate dehydrogenase were higher in the RV pacing group than the sham control and His pacing groups. Notably, the abnormal fatty acid and glucose metabolic pathways in the left ventricular myocardium during RV pacing could be corrected by His bundle pacing. CONCLUSIONS: His bundle pacing can mitigate the abnormal metabolism disorders, endoplasmic reticulum stress, and inflammation induced during RV pacing and may contribute to the superiority of conduction system pacing over RV pacing in reducing heart failure hospitalization.


Assuntos
Fascículo Atrioventricular , Cardiomiopatias , Animais , Suínos , Miocárdio , Ventrículos do Coração , Glucose , Inflamação , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia
6.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38340330

RESUMO

AIMS: A dual-chamber pacemaker with closed-loop stimulation (CLS) mode is effective in reducing syncopal recurrences in patients with asystolic vasovagal syncope (VVS). In this study, we explored the haemodynamic and temporal relationship of CLS during a tilt-induced vasovagal reflex. METHODS AND RESULTS: Twenty patients underwent a tilt test under video recording 3.9 years after CLS pacemaker implantation. Three patients were excluded from the analysis because of no VVS induced by the tilt test (n = 1) and protocol violation (n = 2). In 14 of the remaining 17 patients, CLS pacing emerged during the pre-syncopal phase of circulatory instability when the mean intrinsic heart rate (HR) was 88 ± 12 b.p.m. and systolic blood pressure (SBP) was 108 ± 19 mmHg. The CLS pacing rate thereafter rapidly increased to 105 ± 14 b.p.m. within a median of 0.1 min [inter-quartile range (IQR), 0.1-0.7 min] when the SBP was 99 ± 21 mmHg. At the time of maximum vasovagal effect (syncope or pre-syncope), SBP was 63 ± 17 mmHg and the CLS rate was 95 ± 13 b.p.m. The onset of CLS pacing was 1.7 min (IQR, 1.5-3.4) before syncope or lowest SBP. The total duration of CLS pacing was 5.0 min (IQR, 3.3-8.3). Closed-loop stimulation pacing was not observed in three patients who had a similar SBP decrease from 142 ± 22 mmHg at baseline to 69 ± 4 mmHg at the time of maximum vasovagal effect, but there was no significant increase in HR (59 ± 1 b.p.m.). CONCLUSION: The reproducibility of a vasovagal reflex was high. High-rate CLS pacing was observed early during the pre-syncopal phase in most patients and persisted, although attenuated, at the time of maximum vasovagal effect. REGISTRATION: ClinicalTrials.gov identifier: NCT06038708.


Assuntos
Marca-Passo Artificial , Síncope Vasovagal , Humanos , Estimulação Cardíaca Artificial/métodos , Hemodinâmica , Marca-Passo Artificial/efeitos adversos , Reprodutibilidade dos Testes , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/prevenção & controle , Teste da Mesa Inclinada/métodos
7.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409896

RESUMO

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagem , Eletrocardiografia/métodos , Cateteres
8.
Nat Commun ; 15(1): 64, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167848

RESUMO

There is an urgent clinical need for a treatment regimen that addresses the underlying pathophysiology of ventricular arrhythmias, the leading cause of sudden cardiac death. The current report describes the design of an injectable hydrogel electrode and successful deployment in a pig model with access far more refined than any current pacing modalities allow. In addition to successful cardiac capture and pacing, analysis of surface ECG tracings and three-dimensional electroanatomic mapping revealed a QRS morphology comparable to native sinus rhythm, strongly suggesting the hydrogel electrode captures the deep septal bundle branches and Purkinje fibers. In an ablation model, electroanatomic mapping data demonstrated that the activation wavefront from the hydrogel reaches the mid-myocardium and endocardium much earlier than current single-point pacing modalities. Such uniform activation of broad swaths of tissue enables an opportunity to minimize the delayed myocardial conduction of heterogeneous tissue that underpins re-entry. Collectively, these studies demonstrate the feasibility of a new pacing modality that most closely resembles native conduction with the potential to eliminate lethal re-entrant arrhythmias and provide painless defibrillation.


Assuntos
Fascículo Atrioventricular , Hidrogéis , Animais , Suínos , Fascículo Atrioventricular/fisiologia , Estimulação Cardíaca Artificial/métodos , Ramos Subendocárdicos , Eletrodos , Arritmias Cardíacas/terapia , Eletrocardiografia/métodos
9.
Pacing Clin Electrophysiol ; 47(2): 211-221, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38265169

RESUMO

BACKGROUND: Conduction system pacing (CSP) is increasingly utilized to prevent and correct dyssynchrony. Barriers to CSP adoption include limited training, methodologic variability, laboratory slot allocation, and few data on learning curves. We report learning curves/clinical outcomes from a single experienced electrophysiologist who was new to CSP, and share gained insights. METHODS: Retrospective analysis of all patients who underwent attempted CSP implantation (2016-2023). Patient characteristics, ECGs, echocardiograms, fluoroscopy/procedure times, lead data were recorded at implant and follow-up. RESULTS: CSP leads were implanted successfully in 167/191(87.4%) patients with a follow-up of 278 ± 378 days. His-bundle pacing (HBP = 59) and left-bundle-area pacing (LBAP = 108) had similar procedure/fluoroscopy times, QRS duration decreases, and ejection fraction improvements (all p > NS). Eight HBP lead revisions were required for high capture thresholds LBAP demonstrated lower pacing thresholds, higher lead impedances, and greater R-wave amplitudes at implant and follow-up. After 25 HBP cases, implant pacing thresholds, fluoroscopy, procedural times did not decrease. After 25 LBAP cases, there were significant decreases in all these parameters (p < 0.05). A separate analysis in LBAP patients with recorded Purkinje signals showed no differences in paced ECG characteristics between patients with pre- QRS Purkinje signals versus patients with Purkinje signals post-QRS onset. CONCLUSIONS: Experienced implanters who are new to CSP can achieve steady-state procedural/fluoroscopy times after a learning curve of 25 implants. LBAP showed lower capture thresholds and higher success rates. Adequate depth of lead deployment (as determined by published parameters) does not require Purkinje potential to be pre-QRS. Operators new to CSP.can forego HBP and directly implement LBAP.


Assuntos
Fascículo Atrioventricular , Curva de Aprendizado , Humanos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/métodos , Doença do Sistema de Condução Cardíaco , Eletrocardiografia/métodos , Resultado do Tratamento
10.
Circ Arrhythm Electrophysiol ; 17(2): e012473, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38284238

RESUMO

BACKGROUND: Right ventricular apical pacing (RVAP) can produce left ventricle dysfunction. Conduction system pacing (CSP) has been used successfully to reverse left ventricle dysfunction in patients with left bundle branch block. To date, data about CSP prevention of left ventricle dysfunction in patients with preserved left ventricular ejection fraction (LVEF) are scarce and limited mostly to nonrandomized studies. Our aim is to demonstrate that CSP can preserve normal ventricular function compared with RVAP in the setting of a high burden of ventricular pacing. METHODS: Consecutive patients with a high-degree atrioventricular block and preserved or mildly deteriorated LVEF (>40%) were included in this prospective, randomized, parallel, controlled study, comparing conventional RVAP versus CSP. RESULTS: Seventy-five patients were randomized, with no differences between basal characteristics in both groups. The stimulated QRS duration was significantly longer in the RVAP group compared with the CSP group (160.4±18.1 versus 124.2±20.2 ms; p<0.01). Seventy patients were included in the intention-to-treat analyses. LVEF showed a significant decrease in the RVAP group at 6 months compared with the CSP group (mean difference, -5.8% [95% CI, -9.6% to -2%]; P<0.01). Left ventricular end-diastolic diameter showed an increase in the RVAP group compared with the CSP group (mean difference, 3.2 [95% CI, 0.1-6.2] mm; P=0.04). Heart failure-related admissions were higher in the RVAP group (22.6% versus 5.1%; P=0.03). CONCLUSIONS: Conduction system stimulation prevents LVEF deterioration and heart failure-related admissions in patients with normal or mildly deteriorated LVEF requiring a high burden of ventricular pacing. These results are only short term and need to be confirmed by further larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT06026683.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Ventrículos do Coração , Estudos Prospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Doença do Sistema de Condução Cardíaco , Resultado do Tratamento
11.
Semin Cardiothorac Vasc Anesth ; 28(1): 38-46, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38284295

RESUMO

Since their initial approval by the Food and Drug Administration in 2016, leadless pacemakers have become increasingly prevalent. This growth has been driven by an improved adverse effect profile when compared to traditional pacemakers, including lower rates of infection, as well as eliminated risk of pocket hematoma and lead complications. More recently, technology enabling leadless synchronized atrioventricular pacing in patients with atrioventricular block has vastly expanded the indications for these devices. Anesthesiologists will increasingly be relied upon to safely care for patients with leadless pacemakers undergoing non-electrophysiology procedures and surgery. This article provides an overview of the technology, evidence base, current indications, and unique perioperative considerations for leadless pacemakers.


Assuntos
Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Desenho de Equipamento
12.
Future Cardiol ; 20(1): 21-25, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38223918

RESUMO

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Assuntos
Bloqueio Atrioventricular , Defeitos dos Septos Cardíacos , Marca-Passo Artificial , Humanos , Ventrículos do Coração/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos , Bloqueio Atrioventricular/terapia , Átrios do Coração/diagnóstico por imagem
13.
Pacing Clin Electrophysiol ; 47(2): 260-264, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37221915

RESUMO

The His-bundle has several locations from which conduction system pacing can be achieved. Some locations offer better sensing, thresholds and paced QRS durations. Existing techniques to aid repositioning of an already deployed, but sub-optimally placed lead, include either simple memory of the initial lead position combined with its observation on an x-ray review screen or utilizing an additional vascular access and pacing lead with the first lead serving as a real-time marker (Two-lead technique). We describe a novel, readily available, cost-efficient, imaging-based approach to assist in the re-positioning of a pacing lead for His-bundle pacing (the Image Overlay Technique).


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Humanos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fascículo Atrioventricular , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 47(1): 101-105, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37158275

RESUMO

Coronary artery lesions related to pacemaker implantation are rare complications. With the increasing adoption of the technique of permanent transseptal pacing of the left bundle branch area pacing (LBBAP), an increase in the incidence of these complications may be expected. We report two cases of coronary lesions after permanent transeptal pacing of the LBBAP: the first with a small coronary artery fistula, and the second with an extrinsic coronary compression. Both complications occurred with stylet-driven pacing leads with extendable helix. In the first case, since the shunt volume was small and no major complications were reported, the patient was treated conservatively with good outcome. The second case required lead repositioning due to acute decompensated heart failure.


Assuntos
Insuficiência Cardíaca , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Vasos Coronários , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/prevenção & controle , Fascículo Atrioventricular , Resultado do Tratamento
15.
Cardiol J ; 31(1): 147-155, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37246458

RESUMO

Since the arrival of leadless pacemakers (LPs), they have become a cornerstone in remedial treatment of bradycardia and atrioventricular (AV) conduction disorders, as an alternative to transvenous pacemakers. Even though clinical trials and case reports show indisputable benefits of LP therapy, they also bring some doubts. Together with the positive results of the MARVEL trials, AV synchronization has become widely available in LPs, presenting a significant development in leadless technology. This review presents the Micra AV (MAV), describes major clinical trials, and introduces the basics of AV synchronicity obtained with the MAV and its unique programming options.


Assuntos
Lipopolissacarídeos , Marca-Passo Artificial , Humanos , Desenho de Equipamento , Bradicardia/diagnóstico , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos
16.
Pediatr Cardiol ; 45(2): 361-367, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38062259

RESUMO

Sinus node dysfunction (SND) with junctional rhythm (JR) is common after the Fontan operation. Atrial pacing (AP) restores atrioventricular (AV) synchrony, but the placement of a pacemaker carries significant morbidity. To study the impact of AP on echocardiographic parameters of function in Fontan patients with SND and JR. Nine Fontan patients with AP for SND and JR were prospectively studied with echocardiography in the following conditions-baseline paced rhythm, underlying JR and, if possible, slow-paced rhythm below their baseline paced rate (~ 10 bpm faster than their JR rate). Cardiac index was significantly lower in JR (3 ± 1.1 L/min/m2) vs AP (4.2 ± 1.4 L/min/m2; p = 0.002). Diastolic function also significantly worsened with increased ratio of early diastolic systemic AV valve inflow velocity to early diastolic systemic AV valve annulus velocity (E/e' ratio) by tissue Doppler imaging (TDI) in JR (11.6 ± 4.6) vs AP (8.8 ± 2.2, p = 0.016). Pulmonary venous flow reversal was present in 7/9 patients in JR vs 0/9 in AP (p = 0.016). There were no significant differences in these echocardiographic measurements between the paced and slow-paced conditions. When compared to AP, JR was associated with a significant reduction in cardiac output and diastolic function, and an increased prevalence of pulmonary vein flow reversal. There were no differences between paced and slow-paced conditions, suggesting that AV synchrony rather than heart rate was primarily contributing to cardiac output. Further studies are needed to understand the chronic impact of JR on Fontan outcomes.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Humanos , Estudos Prospectivos , Estimulação Cardíaca Artificial/métodos , Átrios do Coração/diagnóstico por imagem , Arritmias Cardíacas , Síndrome do Nó Sinusal
17.
J Cardiovasc Electrophysiol ; 35(1): 120-129, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37962088

RESUMO

INTRODUCTION: Implant procedure features and clinical implications of left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) have not been yet fully described. We sought to compare two different left bundle branch area pacing (LBBAP) implant strategies: the first one accepting LVSP as a procedural endpoint and the second one aiming at achieving LBBP in every patient in spite of evidence of previous LVSP criteria. METHODS: LVSP was accepted as a procedural endpoint in 162 consecutive patients (LVSP strategy group). In a second phase, LBBP was attempted in every patient in spite of achieving previous LVSP criteria (n = 161, LBBP strategy group). Baseline patient characteristics, implant procedure, and follow-up data were compared. RESULTS: The final capture pattern was LBBP in 71.4% and LVSP in 24.2% in the LBBP strategy group compared to 42.7% and 50%, respectively, in the LVSP strategy group. One hundred and eighty-four patients (57%) had proven LBB capture criteria with a significantly shorter paced QRS duration than the 120 patients (37%) with LVSP criteria (115 ± 9 vs. 121 ± 13 ms, p < .001). Implant parameters were comparable between the two strategies but the LBBP strategy resulted in a higher rate of acute septal perforation (11.8% vs. 4.9%, p = .026) without any clinical sequelae. Patients with CRT indications significantly improved left ventricular ejection fraction (LVEF) during follow-up irrespective of the capture pattern (from 35 ± 11% to 45 ± 14% in proven LBBP, p = .024; and from 39 ± 13% to 47 ± 12% for LVSP, p = .003). The presence of structural heart disease and baseline LBBB independently predicted unsuccessful LBB capture. CONCLUSION: The LBBP strategy was associated with comparable implant parameters than the LVSP strategy but resulted in higher rates of septal perforation. Proven LBB capture and LVSP showed comparable effects on LVEF during follow-up.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Volume Sistólico , Eletrocardiografia/métodos , Função Ventricular Esquerda
18.
Ann Noninvasive Electrocardiol ; 29(1): e13098, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37997513

RESUMO

OBJECTIVE: This systematic review of literature aimed to evaluate the safety and efficacy of dual-chamber ICDs for LBBAP in patients with left bundle branch block (LBBB). METHODS: Digital databases were searched systematically to identify studies reporting the left bundle branch area pacing (LBBAP) with implantable cardioverter defibrillator (ICD) placement in patients with LBBB. Detailed study and patient-level baseline characteristics including the type of study, sample size, follow-up, number of cases, age, gender, and baseline characteristics were abstracted. RESULTS: In a total of three studies, 34 patients were included in this review. There was a significant improvement reported in QRS duration in all studies. The mean QRS duration at baseline was 170 ± 17.4 ms, whereas the follow-up QRS duration at follow-up was 121 ± 17.3 ms. Two studies reported a significant improvement of 50% in LVEF from baseline. No lead-related complications or arrhythmic events were recorded in any study. The findings of the systematic review suggest that dual-chamber ICD for LBBAP is a promising intervention for patients with heart conditions. CONCLUSION: The procedure offers significant improvements in QRS duration and LVEF, and there were no lead-related complications or arrhythmic events recorded in any of the studies.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Bloqueio de Ramo/terapia , Resultado do Tratamento , Estimulação Cardíaca Artificial/métodos , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/métodos
19.
Ann Noninvasive Electrocardiol ; 29(1): e13099, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37997537

RESUMO

BACKGROUND: The temporary pacing lead routinely is placed into right ventricular (RV), which pose a risk of dislocation and cardiac perforation. OBJECTIVE: We aim to evaluate the effectiveness and safety of temporary transvenous cardiac pacing (TTCP) leads placement into the coronary sinus vein (CSV) in patients with sick sinus syndrome (SSS). METHODS: We investigated patients with SSS who underwent TTCP lead placement into the CSV under the guidance of X-ray between January 2013 and May 2023. Patients were randomly divided into two groups: RV group (n = 33) and CSV group (n = 22). The ordinary passive bipolar electrodes were applied in both groups. In RV groups, electrodes were placed into RV. In CSV group, electrodes were placed into CSV. We evaluated the operation duration, fluoroscopic exposure, first-attempt success rate of leads placement, pacing threshold, success rate of leads placement, rate of leads displacement, and complications. RESULTS: Compared with that in RV group, the procedure time, fluoroscopic exposure was significantly prolonged, while the first-attempt success rate of lead placement was obviously increased in CSV group (both p < .05). Compared with that in RV group, the rate of leads displacement is lower in CSV group (both p < .05). There were three patients occurred cardiac perforation in RV group, but no cardiac perforation was reported in CSV group (p > .05). CONCLUSION: TTCP leads placement into the CSV is an effective and safe strategy in patients with SSS. It indicates a high rate of pacing effectiveness with low device replacement and complication rates.


Assuntos
Seio Coronário , Marca-Passo Artificial , Humanos , Seio Coronário/diagnóstico por imagem , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Síndrome do Nó Sinusal/terapia , Eletrocardiografia
20.
Int J Cardiol ; 397: 131608, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38030042

RESUMO

BACKGROUND: Mechanical compression of cardiac conduction system by transcatheter heart valves leads to complete atrioventricular block (CAVB) after transcatheter aortic valve replacement (TAVR). Bulging of ventricular septum in the left ventricular outflow tract (LVOT) may be associated with greater compression of conduction system, leading to irreversible CAVB. OBJECTIVE: This study aimed to investigate the association of ventricular septal bulging with TAVR-related CAVB and permanent pacemaker implantation (PPI). METHODS: Among 294 consecutive patients with severe aortic stenosis who underwent TAVR between July 2017 and February 2023, 271 were included in the analysis. As a quantitative evaluation of bulging of the ventricular septum, the ratio of LVOT area to aortic annulus area (L/A ratio) was measured at the systolic phase of computed tomography images. RESULTS: TAVR-related CAVB occurred in 64 patients (23.6%). Twenty-eight patients (10.3%) required PPI. The optimal thresholds of L/A ratio for predicting TAVR-related CAVB and PPI were 1.0181 and 0.985, respectively. Patients with less than the cut-off values had higher rate of TAVR-related CAVB and PPI than those above (28.3% vs 13.1%, p = 0.0063; 14.7% vs 4.4%, p = 0.0077, respectively). A multivariate analysis showed that L/A ratio < 1.0181 was an independent predictor of TAVR-related CAVB (odds ratio [OR] 2.65, p = 0.011), in addition to prior right bundle branch block (OR 3.76, p = 0.0005), use of a self-expanding valve (OR 1.99, p = 0.030), and short membranous septum length (OR 0.96, p = 0.037). Only L/A ratio < 0.985 was independently associated with PPI (OR 3.70, p = 0.011). CONCLUSION: Low L/A ratio is a predictor of TAVR-related CAVB and PPI.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Bloqueio Atrioventricular/diagnóstico por imagem , Bloqueio Atrioventricular/etiologia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...